Blog

Bonn Agreement oil appearance code explained for terminal HSE officers

Aerial view of a tanker moored at an oil terminal berth beside rows of storage tanks.
Photo: Tom Fisk / Pexels

If you've ever stood at the rail with a radio in hand trying to decide whether what's spreading off the berth is a "sheen" or something that needs to go in the incident log as "rainbow," you've already run into the Bonn Agreement oil appearance code without necessarily knowing its name. It's the six-class color scale that European aerial surveillance teams built to turn "there's some oil out there" into something a report can actually use: an appearance class, a rough thickness band, and from that, an estimated volume.

What the code actually classifies

The Bonn Agreement code doesn't measure oil directly. It classifies what the oil looks like on the water surface under daylight, because that's the only thing a surveillance flight (or a terminal watch-stander on the dock) can observe without sampling. Each class corresponds to a thickness range, and each thickness range gets multiplied by the estimated surface area to produce a volume estimate in liters.

The six classes, lightest to heaviest:

  • Sheen: a barely-there, silvery shimmer. The thinnest visible film, typically well under a micron thick.
  • Silver/Grey: slightly more visible than sheen, still sub-micron, often the first thing a lookout actually calls out.
  • Rainbow: the iridescent, oil-on-puddle look everyone recognizes, somewhere in the low single-digit micron range.
  • Metallic: a duller, more opaque sheen than rainbow, sitting a step up in thickness.
  • Discontinuous true oil colour: patches of the oil's actual brown or black color, broken up by clean water between them.
  • Continuous true oil colour: solid coverage of true oil color. The heaviest class on the scale, and the one nobody wants to be writing up.

The jump from "Sheen" to "Continuous True Oil Colour" isn't linear. Most of what gets reported near a berth or mooring sits in the first three classes, because a sheen that's thick enough to show true color usually means an active, ongoing release rather than a residual trace from a hose connection or ballast operation.

Estimating thickness from color, and why that's harder than it sounds

The reason the Bonn code uses ranges instead of single numbers is that color-to-thickness isn't a precise instrument reading. Sun angle, wind chop, water clarity underneath the film and even the color of the hull or quay wall behind the slick all shift how a given thickness looks. Two sheens of the same actual thickness can read differently fifteen minutes apart as the sun moves, which is exactly why daylight sun-glint imagery is useful here: the geometry that makes a thin film visible at all is the same geometry that makes the color classification repeatable from one observation to the next, rather than dependent on whoever happened to be looking at the time.

For a terminal HSE officer, the practical use of the code isn't academic. Most incident reports ask for an appearance description and an estimated extent, and "rainbow sheen, approximately 400 m²" is a defensible, auditable answer in a way that "some oil on the water" is not. It also gives you a consistent vocabulary to hand off between shifts. The officer who spotted it at 0600 and the one writing the final report at 1400 are working from the same six-word scale instead of two different sets of adjectives.

Putting a number on the extent

The color class tells you what you're looking at. Getting a defensible area for that sheen, especially one that's drifted or spread since it was first spotted, is the part that usually eats the most time before a report can go out. Oil Sheen Detect was built around exactly that gap: it works from daylight satellite imagery to map the sheen's outline and area, and delivers it as a dated sheet alongside the source frame, so the extent in your report is tied to an actual frame rather than a verbal estimate from the dock.

If you're filing a sheen report this week and need the extent documented against imagery rather than a guess, that's the gap Oil Sheen Detect is built to close.

Start a pilot

Back to the blog